Changes between Version 10 and Version 11 of UI5


Ignore:
Timestamp:
2012-04-30 09:45:58 (12 years ago)
Author:
mcvflorin
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • UI5

    v10 v11  
    2525[[Image(ui5_ip_config.png)]] 
    2626 
    27 = UI5 Installation and Setup for IP170/2DS = 
     27== UI5 Installation and Setup for IP170/2DS == 
    2828 
    2929NOTE this is currently beta only and will only work if the IP170/2DS has the correct firmware. 
    3030 
    31  * Download the plug-in from [http://code.mios.com/trac/mios_dscalarmpanel/changeset/74/branches/2ds?old_path=%2F&format=zip this ]location. 
    32  * Install as per the above procedure and follow the creation instructions for The IT100 and WIZnet; however for the IP address the port needs to be changed to 4025 instead of 5000. 
    33  * After the Plugin is created, open the advanced tab of the parent device and change the !InterfaceType variable from IT100 to 2DS then Save. 
     311. Download the plug-in from [http://code.mios.com/trac/mios_dscalarmpanel/changeset/74/branches/2ds?old_path=%2F&format=zip this ]location. 
     322. On the Vera UI go to '''Apps''' >> '''Develop Apps''' >> '''Luup files''' and upload all the files from that archive. Do not check ''Restart Luup after upload''. If it's checked, uncheck it. Click '''GO''' to upload the files on Vera. 
     333. Go to '''Create device'''. 
     34 * In the '''Description''' field enter ''DSC Alarm Panel''. 
     35 * In the '''Upnp Device Filename''' field enter ''D_DSCAlarmPanel1.xml''. 
     36 * In the '''Ip Address''' field enter the IP address and port of the 2DS. The port is ''4025''. E.g. if the IP address of the 2DS is ''192.168.81.63'' the IP Address field must look like this: ''192.168.81.63:4025''. 
     37 * Click on the '''Create device''' button to create the device. 
     384. Reload Luup. 
     395. After the plugin is created, open the control panel of the parent device (the one called ''DSC Alarm Panel'') by clicking on the wrench, go to the '''Advanced''' tab, scroll to the bottom until you can see the '''!InterfaceType''' field and change it from ''IT100'' to '''''2DS'''''. 
     406. Save.