| 145 | For Zone labels by default the plugin will use the default ones programmed in the panel, if labels were never programmed, or were programmed before the IT100 was installed, then the default labels for the sensors the plugin creates will be named "zone 01, zone 02 etc etc, and they cannot not be renamed by default. It is best to try and rectify this with the alarm itself first, however this behavior can be changed by editing the '''EnableManualLabels''' variable in the advanced tab of the alarm parent device from '''false''' to '''true''' and then performing a save at the top of the dashboard; it will then possible to rename. |
| 146 | |
| 147 | If its preferred that the plugin uses the default mechanism of using the labels from the Alarm System, there are usually several ways to rectify the above behavior without changing the above variable: |
| 148 | |
| 149 | * If labels have previously been programmed in a keypad, then attempt a label broadcast from the keypad they were originally programmed from by entering *8[Installer code]*998* |
| 150 | * If labels were never programmed then they can be programmed them from an alpha numeric keypad and a subsequent a label broadcast |
| 151 | * Program the labels to the panel using DSC DLS software |
| 152 | |