Changes between Version 9 and Version 10 of Wiki Start


Ignore:
Timestamp:
2011-10-13 19:39:59 (13 years ago)
Author:
mcvflorin
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • Wiki Start

    v9 v10  
    30302. On the Vera dashboard, go to ''MiOS Developers'' -> ''Luup Files'' and upload all 8 files you downloaded. 
    31313. If ''Restart Luup after upload'' is checked, uncheck it, then click ''GO''. 
    32 4. Go to ''Create Device''; in the ''!UpnpDevFilename'' field enter ''D_ElkAlarmPanel1.xml'' and in the ''Description'' field enter ''Elk M1 Alarm Panel'' (or any name you want). If the panel is connected to Vera on the Ethernet port, enter the IP address and port in the ''!IpAddress'' field (e.g. 192.168.8.23:5000). Press the ''Create Device'' button. 
     324. Go to ''Create Device''; in the ''!UpnpDevFilename'' field enter ''D_ElkAlarmPanel1.xml'' and in the ''Description'' field enter ''Elk M1 Alarm Panel'' (or any name you want). If the panel is connected to Vera on the Ethernet port (using Elk M1XEP or an RS232-to-Ethernet adapter), enter the IP address and port in the ''!IpAddress'' field (e.g. 192.168.8.23:5000). Press the ''Create Device'' button. 
    33335. Restart Luup by clicking the curving arrows in the upper right corner in the dashboard. 
    34346. After Luup has restarted, reload the web page. (best use <Ctrl + F5> to do so) 
    3535 
    3636=== Setup === 
    37 After the plugin has been installed. 
     37If the panel has been connected to Vera on an USB port, you must configure the serial port. 
     381. Go to ''MiOS developers'' -> ''Serial port configuration''. 
     39** Set the ''Baud'' to '''115200'''. 
     40** Select the newly created panel device from the ''Used by device'' drop-down list. 
     41** Optionally you can give a name to this serial port in the ''Name'' field. 
     422. Close this window and click ''SAVE''. 
     433. After Luup has restarted reload the web page. 
     44[[Image(serial_port_configuration.png)]] 
    3845 
    3946=== Usage ===