    77The product page for this device is [http://www.eguestcontrols.com/products/director-series-controllers/lcd-1/ here]. 
    88 
    9 It should also work with the LCD-1 Tabletop model (LCD-1TT) as well as the dual-gang LCD1/Switch (LCD-2) but probably not with the LCD-3 or LCD-D. 
     9It also works with the LCD-1 Tabletop model (LCD-1TT) as well as the dual-gang LCD1/Switch (LCD-2) as well as the new round button dual-scene 3-scene and 4-scene models but probably not with the LCD-3 or LCD-D. 
    1010 
    1111Before this plug-in, you cold install an Evolve LCD1 into Vera just like any other Z-Wave device and it works as a generic 5-button scene controller. However, you could not modify the LCD screen or take advantage of other advanced features. 
     
    1313This plug-in not only allows you to set the LCD labels but also allows you to change screens. The scenes triggered when you press a button depends on the current screen. 
    1414 
    15 This is an early pre-release version which I wanted to release for comments. Not all planned features are yet implemented. 
     15The Evolve LCD-1 controller can also act as a remote thermostat controller and display for separate Z-Wave thermostats such as the Evolve T100R Thermostat. The temperature from other temperature sensors can also be displayed. 
     16 
     17Version 0.8 is a major new release with many new features. This however, is still work-in-progress so expect new features and bug-fixes. 
    1618 
    1719=== Currently working features === 
     
    1921* Switch between 9 different screens from the Vera dashboard 
    2022* Select labels for 6 different custom screens. Each screen can have 5 labels and each label can have 1 or 2 lines of text. 
    21 * Each screen can trigger 5 different scenes. Toggle mode buttons have separate activate and deactivate scenes. 
     23* Each custom label can either be in normal, condensed, or inverted font and can be left, center, or right-justified. 
     24* Each screen can trigger 5 different scenes. Each button can be programmed in several different modes: Momentary, Toggle, Exclusive, and Switch Screen. 
     25* Select from 6 temperature screens. The first two have fixed labels. The other four can be programmed with custom top and bottom labels. Each temperature screen can be associated with a different thermostat or temperature sensor 
     26* Screens have an optional timeout which will automatically switch to a designated screen if there is no user activity within a specified time. 
    2227* Detailed configuration options predefined in the Device Option tab. 