= GCE IPX800v3 roller shutter controller = '''Version''': 2.3 '''Author''': FaTaL25 '''Information''' (in french): http://www.gce-electronics.com/forum/viewtopic.php?f=33&t=868 == Information == Where to buy GCE IPX800v3 - http://www.gce-electronics.com/fr/57-carte-8-relais-ethernet-ip-ipx800-v3.html The card is a Ethernet relay card. It has : - 8 digital inputs - 8 relays - 4 analog inputs - 128 timers... With extensions, you can have: - 32 digital inputs - 32 relays IPX800v3 can control a roller shutter with 2 relays. - 1 relay ON/OFF - 1 relay UP/DOWN but it's not possible to command roller shutter to 30% for example. The plugin can do it for you. For my plugin, I use M2M (machine to machine - TCP socket) == Requirements == You must have: - Vera (3 or lite) - IPX800v3 - at least a shutter connected to your IPX800v3 == Limitations == * UI5 only - Not tested on UI4 * Works only with GCE IPX800v3 with firmware over 3.05.00 == Plugin installation == 1. Upload attached files 2. Restart LUUP engine 3. Create device: "Apps > Develop Apps > Create device" Fill in these fields: * "Description": a name for the device * "Upnp Device Filename": "D_WindowCovering1ipx.xml" * "Upnp Implementation Filename": "I_WindowCovering1ipx.xml" 4. Restart LUUP engine 5. New device has been created and now, you have to configure it. == Plugin Configuration == 1. Go to the tab "Control" 2. Define the cycletime of your roller shutter. Cycletime is the time in seconds the shutter moves the down position to the up position. (0% to 100%) 3. Define GCE IPX800v3 IP adress 4. Define GCE IPX800v3 Port M2M (machine to machine) (default 9870) 5. Define the ON/OFF relay number (1 to 32) 6. Define the UP/DOWN relay number (1 to 32) 7. Restart LUUP engine It's done. Now, assuming that you have a push button connected to your IPX (which is not necessarily required for the plugin but it is more convenient for local orders), you must configure your IPX it sends a command the Vera whenever you press the PB. To do this, go here: http:///protect/settings/push1.htm Select the entry for your BP wired (for example 5) Then enter in the server field the IP of your VERA. Port: 3480 Enable push ticked then SAVE In Push1: /data_request?id=lu_action&!DeviceNum=&serviceId=urn:upnp-org:serviceId:WindowCoveringipx1&action=BP_IPX replace the ID number of the module created earlier in the Vera. (wrench / Advanced / ID field) For initializing the plugin, make an OPEN or CLOSED command and wait 2 cycletimes. Now, you can use your roller shutter like a Fibaro FGR221 :)