| 107 | |
| 108 | == Eco features == |
| 109 | [[Image(Screenshot_04_Eco.png, 50%, right)]] |
| 110 | Eco options are available in case there is an alarm system connected to Vera and/or door/window sensors. |
| 111 | === Alarm partition Eco options === |
| 112 | If there is nobody at home, the plugin offers two options to activate. To determine whether nobody is at home, the state of an alarm partition is used. In case there are multiple partitions, one needs to be selected. |
| 113 | The two available options are: |
| 114 | * Change domestic hot water: one can select to disable DHW when nobody is home |
| 115 | * Change room setpoint: the room setpoint can be lowered compared to the setpoint when arming the partition; or it can be set to a specific value. The TT command is used to set this setpoint, so a program change will override the setpoint. |
| 116 | === Door/window sensor Eco options === |
| 117 | If one or multiple door/window sensors is tripped, the plugin can lower the current room setpoint (or set it to a predefined value). Select the available sensors via the multi-select box. |
| 118 | * Change room setpoint: new setpoint when one of the door/window sensors is tripped (set via TT command) |
| 119 | * Option: only when it is open for more than: select the number of minutes that one of the door/windows has to be open before the setpoint is lowered. |
| 120 | * Option: only when it is colder outside than inside: one can select to only set a new setpoint if it is colder outside than inside. A outside temperature sensor has to be selected in the settings for this to work. |
| 121 | |