Changes between Version 11 and Version 12 of WikiStart
- Timestamp:
- 2014-01-06 23:41:39 (11 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
WikiStart
v11 v12 24 24 25 25 == Version history == 26 * 0.6 January 7, 2014 27 * Corrects namespace conflict for HVAC device 28 * Changed behavior of !EnergyModeStatus; will now be on only if an Eco option is in effect 29 * Eco mode and options added 30 * [EDHW] Change DHW setting when !EnergyModeStatus set to !EnergySavingsMode 31 * [ETMP] Change setpoint when !EnergyModeStatus set to !EnergySavingsMode 32 * Added configuration options for firmware 4.0 33 * 0.5 November 20, 2013 34 * Bug fix; now correctly shows negative values 26 35 * 0.4 October 27, 2013 27 36 * Supports OTG firmware version 4.0(alpha) … … 80 89 81 90 === Hardware === 82 [[Image(Screenshot_0 4_Hardware.png, 50%, right)]]The following settings are available in the 'Hardware' tab.91 [[Image(Screenshot_06_Hardware.png, 50%, right)]]The following settings are available in the 'Hardware' tab. 83 92 * Operating mode - Gateway or Monitor; this should be set to 'Gateway' for all functions to be available. 84 93 * Non-significant transitions - Select whether checking for error 01 is on or off 94 * Remote Override Function flags - Select whether in !MsgId 100 the flags are set in only the low byte or both the high and low byte. If you have a Honeywell Chronotherm Vision Modulation make sure it is set to 'High and low byte' (if not, a TT setting will be permanent). 85 95 * Reference voltage - Select the reference voltage setting (reference voltage is used as a threshold for the comparators) 96 * GPIO A-B - Select a function for each GPIO port 86 97 * LED A-D or A-F function (A-F as of firmware 4) - Select a function for each LED on the Gateway 87 98 * Receiving an Opentherm message from the thermostat or boiler … … 107 118 108 119 == Eco features == 109 [[Image(Screenshot_04_Eco.png, 50%, right)]] 110 Eco options are available in case there is an alarm system connected to Vera and/or door/window sensors. 120 [[Image(Screenshot_06_Eco.png, 50%, right)]] 121 === Default Eco options === 122 The following Eco options are activated when the Eco mode is selected. 123 * Change domestic hot water: one can select to disable DHW or not 124 * Change room setpoint: the room setpoint can be lowered compared to the current setpoint; or it can be set to a specific value. The TT command is used to set this setpoint, so a program change will override the setpoint. 125 126 The following Eco options are only available in case there is an alarm system connected to Vera and/or door/window sensors. 111 127 === Alarm partition Eco options === 112 128 If there is nobody at home, the plugin offers two options to activate. To determine whether nobody is at home, the state of an alarm partition is used. In case there are multiple partitions, one needs to be selected.