  • WikiStart

    v11 v12  
    2424 
    2525== Version history == 
     26* 0.6 January 7, 2014 
     27  * Corrects namespace conflict for HVAC device 
     28  * Changed behavior of !EnergyModeStatus; will now be on only if an Eco option is in effect 
     29  * Eco mode and options added 
     30    * [EDHW] Change DHW setting when !EnergyModeStatus set to !EnergySavingsMode 
     31    * [ETMP] Change setpoint when !EnergyModeStatus set to !EnergySavingsMode 
     32  * Added configuration options for firmware 4.0 
     33* 0.5 November 20, 2013 
     34  * Bug fix; now correctly shows negative values 
    2635* 0.4 October 27, 2013 
    2736  * Supports OTG firmware version 4.0(alpha) 
     
    8089 
    8190=== Hardware === 
    82 [[Image(Screenshot_04_Hardware.png, 50%, right)]]The following settings are available in the 'Hardware' tab. 
     91[[Image(Screenshot_06_Hardware.png, 50%, right)]]The following settings are available in the 'Hardware' tab. 
    8392* Operating mode - Gateway or Monitor; this should be set to 'Gateway' for all functions to be available. 
    8493* Non-significant transitions - Select whether checking for error 01 is on or off 
     94* Remote Override Function flags -  Select whether in !MsgId 100 the flags are set in only the low byte or both the high and low byte. If you have a Honeywell Chronotherm Vision Modulation make sure it is set to 'High and low byte' (if not, a TT setting will be permanent). 
    8595* Reference voltage - Select the reference voltage setting (reference voltage is used as a threshold for the comparators) 
     96* GPIO A-B - Select a function for each GPIO port 
    8697* LED A-D or A-F function (A-F as of firmware 4) - Select a function for each LED on the Gateway 
    8798  * Receiving an Opentherm message from the thermostat or boiler 
     
    107118 
    108119== Eco features == 
    109 [[Image(Screenshot_04_Eco.png, 50%, right)]] 
    110 Eco options are available in case there is an alarm system connected to Vera and/or door/window sensors. 
     120[[Image(Screenshot_06_Eco.png, 50%, right)]] 
     121=== Default Eco options === 
     122The following Eco options are activated when the Eco mode is selected. 
     123* Change domestic hot water: one can select to disable DHW or not 
     124* Change room setpoint: the room setpoint can be lowered compared to the current setpoint; or it can be set to a specific value. The TT command is used to set this setpoint, so a program change will override the setpoint. 
     125 
     126The following Eco options are only available in case there is an alarm system connected to Vera and/or door/window sensors. 
    111127=== Alarm partition Eco options === 
    112128If there is nobody at home, the plugin offers two options to activate. To determine whether nobody is at home, the state of an alarm partition is used. In case there are multiple partitions, one needs to be selected.