Changes between Version 13 and Version 14 of WikiStart
- Timestamp:
- 2014-01-12 21:01:37 (11 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
WikiStart
v13 v14 8 8 9 9 == Supported features == 10 [[Image(Screenshot_ 04_Control.png, 50%, right)]]10 [[Image(Screenshot_10_Control.png, 50%, right)]] 11 11 * Monitor !OpenTherm settings 12 12 * !OpenTherm version 2.3 messages supported … … 72 72 73 73 == Monitor screenshot (UI5) == 74 [[Image(Screenshot_ 04_Monitor.png)]]74 [[Image(Screenshot_10_Monitor.png)]] 75 75 76 76 == Installation == … … 83 83 == Configuration == 84 84 === Settings === 85 [[Image(Screenshot_ 04_Settings.png, 50%, right)]]The following settings are available in the 'Settings' tab.85 [[Image(Screenshot_10_Settings.png, 50%, right)]]The following settings are available in the 'Settings' tab. 86 86 * Communicate using UART - visible when connected via a serial interface 87 87 * Communicate using IP - visible when connected via an IP address … … 93 93 94 94 === Hardware === 95 [[Image(Screenshot_ 06_Hardware.png, 50%, right)]]The following settings are available in the 'Hardware' tab.95 [[Image(Screenshot_10_Hardware.png, 50%, right)]]The following settings are available in the 'Hardware' tab. 96 96 * Operating mode - Gateway or Monitor; this should be set to 'Gateway' for all functions to be available. 97 97 * Non-significant transitions - Select whether checking for error 01 is on or off … … 114 114 115 115 == Usage == 116 [[Image(Screenshot_ 04_Device.png, right)]]116 [[Image(Screenshot_10_Device.png, right)]] 117 117 * Changing a temperature setpoint in the UI will send a 'TT=' command to the Gateway. The Gateway will use this to force a 'Remote override room setpoint'. 118 118 * Pressing the 'Heat' button will send a 'TC=' command, making the current setpoint constant instead of temporary. … … 122 122 123 123 == Eco features == 124 [[Image(Screenshot_ 06_Eco.png, 50%, right)]]124 [[Image(Screenshot_10_Eco.png, 50%, right)]] 125 125 === Default Eco options === 126 126 The following Eco options are activated when the Eco mode is selected. … … 141 141 142 142 == Notifications == 143 [[Image(Screenshot_ 03_Notifications.png, 50%, right)]]143 [[Image(Screenshot_10_Notifications.png, 50%, right)]] 144 144 The following notifications are currently available. 145 145 * Central heating goes on or off … … 159 159 * !PluginLogPath - path to write log file to 160 160 * !PluginHaveChildren - empty: none; otherwise list of message IDs that will create a child device 161 * !PluginEmbedChildren - 0: child devices are separate; 1: child devices are embedded 161 162 * !PluginMonitorBars - 0: none; 1: single color; 2: temperature relative 163 * !PluginUpdateClock - 0: no; 1: only time; 2: date and time; 3: date, time and year 162 164 * !PluginOutsideSensor - empty: none; otherwise device ID of temperature sensor 163 165 * !PluginHumiditySensor - empty: none; otherwise device ID of humidity sensor 164 166 * !PluginEcoMeasureState - empty: none; otherwise a combination of [ADHW], [ATMP], [DTMP] 165 167 * !PluginPartitionDevice - empty: none; otherwise device ID of alarm partition device 168 * PluginEcoDHW - 0: No; 1: disable; 2: automatic 169 * !PluginEcoTemp - 0: no change; x: set to x degrees; -x: lower x degrees 166 170 * PluginArmedAwayDHW - 0: No; 1: disable; 2: automatic 167 171 * !PluginArmedAwayTemp - 0: no change; x: set to x degrees; -x: lower x degrees … … 172 176 173 177 [[Image(Screenshot_04_ChildDevice.png, right)]] 174 Currently not all !OpenTherm messages have associated variables in which the value is stored. The following messages do. If a child device is created, then the value is written to the Gateway variable as well as the '!CurrentTemperature' variable of the child device.178 All !OpenTherm 2.3 messages have associated variables in which the value is stored. If a child device is created, then the value is written to the Gateway variable as well as the '!CurrentTemperature' variable of the child device. 175 179 * 1: !ControlSetpoint 176 * 5: !FaultCode 180 * 2 (lb): !MasterMemberId 181 * 3 (lb): !SlaveMemberId 182 * 4: !RemoteCommand 183 * 5 (lb): !FaultCode 184 * 7: !CoolingControlSignal 185 * 8: CH2ControlSetpoint 177 186 * 9: !RemoteOverrideRoomSetpoint 187 * 10 (hb): TSPNumber 188 * 11 (hb): TSPIndex; (lb): TSPValue 189 * 12 (hb): FHBSize 190 * 13 (hb): FHBIndex; (lb): FHBValue 178 191 * 14: !MaxRelativeModulationLevel 192 * 15 (hb): !MaxBoilerCapacity; (lb): !MinModulationLevel 179 193 * 16: !CurrentSetpoint 180 194 * 17: !RelativeModulationLevel 181 195 * 18: CHWaterPressure 196 * 19: DHWFlowRate 197 * 20: !DayTime 198 * 21: Date 199 * 22: Year 200 * 23: CH2CurrentSetpoint 182 201 * 24: !CurrentTemperature 183 202 * 25: !BoilerWaterTemperature … … 185 204 * 27: !OutsideTemperature 186 205 * 28: !ReturnWaterTemperature 206 * 29: !SolarStorageTemperature 207 * 30: !SolarCollectorTemperature 208 * 31: CH2FlowTemperature 187 209 * 32: DHW2Temperature 210 * 33: !BoilerExhaustTemperature 211 * 48: DHWBounadries 212 * 49: CHBoundaries 213 * 50: OTCBoundaries 188 214 * 56: DHWSetpoint 189 215 * 57: MaxCHWaterSetpoint 216 * 58: OTCHeatCurveRatio 217 * 70: VHStatus 218 * 71 (hb): VHControlSetpoint 219 * 72 (lb): VHFaultCode 220 * 73: VHDiagnosticCode 221 * 74 (lb): VHMemberId 222 * 75: VHOpenThermVersion 223 * 76 (hb): VHProductType; (lb): VHProductVersion 224 * 77: !RelativeVentilation 225 * 78: !RelativeHumidity 226 * 79: CO2Level 227 * 80: !SupplyInletTemperature 228 * 81: !SupplyOutletTemperature 229 * 82: !ExhaustInletTemperature 230 * 83: !ExhaustOutletTemperature 231 * 84: !ExhaustFanSpeed 232 * 85: !InletFanSpeed 233 * 86: VHRemoteParameter 234 * 87: !NominalVentilation 235 * 88 (hb): VHTSPSize 236 * 89 (hb): VHTSPIndex; (lb): VHTSPValue 237 * 90 (hb): VHFHBSize 238 * 91 (hb): VHFHBIndex; (lb): VHFHBValue 190 239 * 100: !RemoteOverrideFunction 240 * 115: OEMDiagnosticCode 241 * 116: !StartsBurner 242 * 117: StartsCHPump 243 * 118: StartsHDWPump 244 * 119: StartsBurnerDHW 245 * 120: !HoursBurner 246 * 121: HoursCHPump 247 * 122: HoursDHWPump 248 * 123: HoursPumpDHW 249 * 124: !MasterOpenThermVersion 250 * 125: !SlaveOpenThermVersion 251 * 126 (hb): !MasterProductType; (lb): !MasterProductVersion 252 * 127 (hb): !SlaveProductType; (lb): !SlaveProductVersion 191 253 192 254 === Gateway === … … 203 265 * StatusOTCActive - Outside temp. comp. active 204 266 * StatusCH2Enabled - Central heating 2 enable 267 * !StatusSummerWinter - Summer/winter mode 268 * StatusDHWBlocked - Domestic hot water blocking 205 269 * !StatusFault - Fault indication 206 270 * StatusCHMode - Central heating mode … … 210 274 * StatusCH2Mode - Central heating 2 mode 211 275 * !StatusDiagnostic - Diagnostic indication 212 ==== Config flag variables ==== 276 ==== Master Config flag variables ==== 277 * !ConfigSmartPower - Smart power present 278 ==== Slave Config flag variables ==== 213 279 * ConfigDHWpresent - Domestic hot water present 214 280 * !ConfigControlType - Control type (modulating on/off) … … 217 283 * !ConfigMasterPump - Master low-off & pump control allowed 218 284 * ConfigCH2 - Central heating 2 present 219 220 285 ==== Fault flag variables ==== 221 222 286 * !FaultServiceRequest - Service request 223 287 * !FaultLockoutReset - Lockout-reset … … 226 290 * !FaultAirPress - Air pressure fault 227 291 * !FaultOverTemp - Water over-temperature 292 ==== Remote flag variables ==== 293 * RemoteDHWEnabled - DHW setpoint enable 294 * RemoteMaxCHEnabled - Max. CH setpoint enable 295 * RemoteDHWReadWrite - DHW setpoint read/write 296 * RemoteMaxCHReadWrite - Max. CH setpoint read/write