@Pestus installation instructions per == Hardware Installation == These instructions are specifically for the Digiplex EVO line of panels. For the older Digiplex DGP line of panels, please consult your installation manual for the equivalent codes. === Physical Connectivity === 1. Be sure you have the PRT3 correctly connected to the panel's bus system, and powered correctly. Do NOT connect this device with the panel powered up!!!! Remove the AC connection AND the battery. Attach the color coded wires from the PRT3 to the main panel's bus. Yellow to Yellow, Green to Green, + to Aux+ or Red, - to Aux- or Black. Then power up by putting the battery back in, and then the AC adapter. You may or may not get a trouble indicating loss of clock. 1. Next, go into installer mode on the alarm. Hold zero on the keypad, until a 6 digit code is asked for. Then type the installer code. (If you must call your alarm dealer for this, they will most likely refuse to give you installer access. The default installer code is 000000) 1. Do a module scan to assure the panel enrolls the PRT3 on the bus properly. enter section [4006]. 1. In section [3035], set switch 7 ON (Transmit zone status on serial port). 1. In section [3035], set switch 8 ON (Serial port baud rate set to 57600). 1. Enter PRT3 Programming by first entering section [4003]. Then, enter the 8 digit serial number of the PRT3. This can be found on a little paper label on the PRT3 board. 1. In section [016], set switch 1 ON (Turns on the serial port) 1. In section [016], set switch 4 ON (Enables Home Automation Integration) 1. In section [016], set switches 2 and 3 ON (This combination sets the baud rate to 56700, to match the panel, and the Vera) 1. Return to main panel programming by hitting clear. 1. If the zone labels in the panel were set prior to all this, enter section [4004]. This will allow Label Broadcast. To transmit the labels, enter 00. Then press the ACC button on the keypad. If you do not have this button, try the FIRE button, or START button. This should send all labels, to all devices provisioned on the bus system. If this does not work, see the next step. === Resetting Zone and Area Labels === 1. If you must manually set the zone labels, or they have not been set at all yet, you must enter keypad programming. Enter section [0000]. This will display the current keypad's serial number. Record it. 1. In section [4003], enter the keypad's serial number to enter keypad programming. 1. In section [201] to [204] you may rename the "Areas". Refer to the EVO programming manual on page 65 for specifics on entering the text itself. 1. In section [101] to [148] you may rename the "Zones". Refer to the EVO programming manual on page 65 for specifics on entering the text itself. 1. Once label programming is complete, hit clear multiple times until out of programming and back to normal operation. Your panel, PRT3, and label programming are complete at this point. === Validate the PRT3 === 1. Connect a USB cable from the PRT3 to a PC (or Mac) 1. Run a terminal program, like Hyper-Terminal, and connect to the COM Port @ 57600 baud 1. Type the command ZL001 and press <Enter> 1. The PRT3 should respond with the Label string for Zone 1 === Attach the PRT3 to Vera === You are now ready to attach the PRT3 to Vera, and complete the configuration. 1. Attach Vera to the Paradox PRT3 Module using a USB Cable === Acknowledgements === These instructions are courtesy of @Pestus in this post: http://forum.micasaverde.com/index.php/topic,2492.msg99977.html#msg99977

Legend:

Unmodified
Added
Removed
Modified
  • Installation-Hardware

    v1 v2  
    11== Hardware Installation  == 
    22 
    3 The following section assumes you have a working Paradox Alarm Panel and have successfully connected, and configured, the Paradox Security PTR3 Printer Module.  
     3These instructions are specifically for the Digiplex EVO line of panels.  For the older Digiplex DGP line of panels, please consult your installation manual for the equivalent codes. 
    44 
    5 Each of these devices comes with instructions for wiring and basic configuration. If you are not comfortable with this type of Wiring and configuration then contact your Alarm installer ''before'' proceeding.  
     5=== Physical Connectivity === 
     61.  Be sure you have the PRT3 correctly connected to the panel's bus system, and powered correctly.  Do NOT connect this device with the panel powered up!!!!  Remove the AC connection AND the battery.  Attach the color coded wires from the PRT3 to the main panel's bus.  Yellow to Yellow, Green to Green, + to Aux+ or Red, - to Aux- or Black.  Then power up by putting the battery back in, and then the AC adapter.  You may or may not get a trouble indicating loss of clock. 
     71.  Next, go into installer mode on the alarm.  Hold zero on the keypad, until a 6 digit code is asked for.  Then type the installer code.  (If you must call your alarm dealer for this, they will most likely refuse to give you installer access.  The default installer code is `000000`) 
     81.  Do a module scan to assure the panel enrolls the PRT3 on the bus properly.  enter section `[4006]`. 
     91.  In section `[3035]`, set switch 7 ON (Transmit zone status on serial port). 
     101.  In section `[3035]`, set switch 8 ON (Serial port baud rate set to 57600). 
     111.  Enter PRT3 Programming by first entering section `[4003]`.  Then, enter the 8 digit serial number of the PRT3.  This can be found on a little paper label on the PRT3 board. 
     121.  In section `[016]`, set switch 1 ON (Turns on the serial port) 
     131.  In section `[016]`, set switch 4 ON (Enables Home Automation Integration) 
     141.  In section `[016]`, set switches 2 and 3 ON (This combination sets the baud rate to 56700, to match the panel, and the Vera) 
     151.  Return to main panel programming by hitting clear. 
     161.  If the zone labels in the panel were set prior to all this, enter section `[4004]`.  This will allow Label Broadcast. To transmit the labels, enter `00`.  Then press the ACC button on the keypad.  If you do not have this button, try the FIRE button, or START button.  This should send all labels, to all devices provisioned on the bus system.  If this does not work, see the next step. 
    617 
    7 Notes  
     18=== Resetting Zone and Area Labels === 
     191.  If you must manually set the zone labels, or they have not been set at all yet, you must enter keypad programming.  Enter section `[0000]`.  This will display the current keypad's serial number.  Record it. 
     201.  In section `[4003]`, enter the keypad's serial number to enter keypad programming. 
     211.  In section `[201]` to `[204]` you may rename the "Areas".  Refer to the EVO programming manual on page 65 for specifics on entering the text itself.  
     221.  In section `[101]` to `[148]` you may rename the "Zones".  Refer to the EVO programming manual on page 65 for specifics on entering the text itself.  
     231.  Once label programming is complete, hit clear multiple times until out of programming and back to normal operation. 
    824 
    9   * Configure the PTR3 Module Baud Rate 
     25Your panel, PRT3, and label programming are complete at this point. 
    1026 
    11   In Paradox EVO Alarm Panels this is Section `[016]` and in Spectra Alarm Panels this is Section `[553]` of the Alarm Panel configuration.  The Baud Settings should be configured to `57600` Baud by setting both Options `[2] & [3]` to `[ON]`.  You can use a lower Baud rate, but it will slow the communications between Vera and the Alarm Panel. 
     27=== Validate the PRT3 === 
     281. Connect a USB cable from the PRT3 to a PC (or Mac) 
     291. Run a terminal program, like Hyper-Terminal, and connect to the COM Port @ 57600 baud 
     301. Type the command `ZL001` and press ''<Enter>'' 
     311. The PRT3 should respond with the Label string for ''Zone 1'' 
    1232 
    13   * Configure the PTR3 Module for Home Automation 
     33=== Attach the PRT3 to Vera === 
     34You are now ready to attach the PRT3 to Vera, and complete the configuration.   
     351. Attach Vera to the Paradox PRT3 Module using a USB Cable 
    1436 
    15   In Paradox EVO Alarm Panels, this is Section `[016]`, Option `[4]`. It should be set to `[ON]` 
    1637 
    17   * Set any Zone Labels '''after''' you connect the PRT3 Module to the Combus 
    18  
    19   Only Zone Labels changed/modified ''after'' PRT3 is attached will be correctly recorded in the PRT3 Module. If you set the Zone Labels prior to connecting the PRT3, it'll only list "Default" Labels for each Zone. The Vera-Luup Alarm interface code will skip over these as if they're ''unused'' Zones. Please use the Alarm Panel's Reference and Installation manuals to determine how to setup your Zone Labels. 
    20   If you've attached the PRT3 Module to an existing Alarm Panel, you can simply re-enter the Zone Labels to "trigger" it to get a copy of them. 
    21  
    22   * Attach Vera to the Paradox PRT3 Module using a USB Cable 
    23   After attaching Vera to the Paradox PRT3 Module, navigate to the following pane in Vera: 
    24     ''Toolbox'' >> ''MiOS Developers'' >> ''Serial Port configuration'' 
    25   which should show settings similar to these [[Image(ParadoxAlarm-VeraSerialConfig-UI4.png, align=right, 30%)]]  You can now change the Baud rate to `57600`, matching the Alarm Panel, and press '''(Save)'''. 
     38=== Acknowledgements === 
     39These instructions are courtesy of @Pestus in this post: 
     40    http://forum.micasaverde.com/index.php/topic,2492.msg99977.html#msg99977