45 | | ! *''Note'': On the older software versions of the Powerlink enrollment needs to be done manually on the !PowerMax. So if you don't enroll the Powerlink on the !PowerMax the plugin will operate in standard mode, and if enrolled in Powerlink mode. |
46 | | On the newer software versions of the !PowerMax the Powerlink enrollment is automatic, and the plugin should only operate in Powerlink mode (if enrollment is successful). |
| 45 | ! *''Note'': On the older software versions of the Powerlink enrollment needs to be done manually on the !PowerMax. So if you don't enroll the Powerlink on the !PowerMax the plugin will operate in 'Standard' mode, and if enrolled in 'Powerlink' mode. |
| 46 | On the newer software versions of the !PowerMax the Powerlink enrollment is automatic, and the plugin should only operate in 'Powerlink' mode (if enrollment is successful). See 'Settings' below how to force the plugin to use 'Standard' mode if needed. |
48 | | == Variables == |
49 | | The following configuration variables can be set on the panel. |
50 | | * In Powerlink mode only |
51 | | * !AutoCreate [0|1] - When '1', reads the settings from the panel to create devices |
52 | | * !AutoSyncTime [0|1] - When '1', syncs time between Vera & !PowerMax after each download |
53 | | * !ForceStandard [0|1] - When '1', will force the plugin to use Standard mode and not enroll |
54 | | * !PluginDebug [0|1] - When '1', creates debug info as well as 'powermax_pdu.txt' and 'powermax_settings.txt' files |
| 48 | == Settings & variables == |
| 49 | [[Image(panel_settings.png, 50%, right)]]The following settings are available in the 'Settings' tab. |
| 50 | * General options |
| 51 | * Communicate using UART - select the USB UART interface for communication with the !PowerMax |
| 52 | * Motion sensor timeout - select the number of minutes a motion sensor will be displayed as 'tripped' |
| 53 | * Language selection - select the language in which the status of the panel & partition is displayed |
| 54 | * !PluginDebug - When 'On', creates debug info as well as 'powermax_pdu.txt' and 'powermax_settings.txt' files |
| 55 | |
| 56 | * Powerlink options (used in Powerlink mode only) |
| 57 | * Force Standard mode - When 'On', will force the plugin to use Standard mode and not enroll |
| 58 | * Auto-create devices - When 'On', reads the settings from the panel to create devices |
| 59 | * Auto-sync time on startup - When 'On', syncs time between Vera & !PowerMax after each download (when starting the plugin) |
| 60 | |
| 61 | The following configuration variables can be set on the 'Advanced' tab of the panel. '''Make sure the '!AutoCreate' is set to off - otherwise these values are overwritten.''' |