= UI5 Installation and Setup = == Setup == First go to '''Apps''' >> '''Install Apps''' and install the plugin, then follow the steps below: 1. In the alarm panel device control panel open the '''Advanced''' tab and enter the number of active partitions in the '''!NumPartitions''' input field. '''Warning:''' The plugin might not work correctly if this number is incorrect. [[Image(ui5_num_partitions.png)]] 2. Save. After restart, a device for each partition is created (e.g ''Ademco Vista Partition 1''). 3. In the partition's control panel, open the '''Advanced''' tab and in the '''!KeypadAddresses''' input field enter the addresses of the keypads assigned to this partition. If there are more than one keypad for a partition, enter the addresses of each keypad separated by a comma (e.g. If the keypads at addresses 17, 19 and 23 are assigned to this partition, the ''!KeypadAddresses'' will be ''17,19,23''). Repeat this for all the partition devices. '''NOTE !#1:''' The AD2USB's address should be added to the keypad addresses list for any partition. '''NOTE !#2:''' If the ''!KeypadAddresses'' field doesn't exist, reload the web page. '''WARNING''': The plugin won't work correctly if these variables aren't correctly set. [[Image(ui5_keypad_addresses.png)]] 4. Save. 5. Go to '''Apps''' -> '''Develop Apps''' -> '''Serial Port configuration'''. Set the '''Baud''' to ''115200'' and select the alarm panel device from the '''Used by device''' drop-down list. Optionally, you can enter a name for the serial port in the '''Name''' field. '''NOTE:''' If the port is not on the serial port list, first make sure that the AD2USB is connected to Vera, then restart Luup. After restart, try this step again. [[Image(ui5_serial_port_config.png)]] 6. Save. If everything works OK you should see the partition status updating.