Last modified 12 years ago Last modified on 2012-09-16 05:18:59

Direct transfer Installation and Setup

UI4

  1. Download these files from http://code.mios.com/trac/mios_caddxnx584/browser/trunk and transfer them all to Vera:
  1. Go to MiOS developers -> Create device.
    • In the UpnpDevFilename text box, enter D_CaddxNX584Security.xml.
    • Give the device a name in the Description text box.
  2. Go to Serial Port Configuration and assign the serial port (local or IPSerial) to the Luup device you just created.
  3. Save.
  4. After Luup restarts, refresh the browser.

The plugin creates a device for the alarm system, and one device for each alarm partition. Partitions are detected automatically.

UI5

  1. Download these files from http://code.mios.com/trac/mios_caddxnx584/browser/trunk and transfer them all to Vera through the web UI (Apps > Develop Apps > Luup Files > Upload Files):
  1. If you are on firmware 1.5.261 or later, skip this step. Download this file from http://code.mios.com/trac/mios_caddxnx584/browser/trunk and use scp to transfer it to the /etc/cmh-ludl directory Vera:

(Installing this file through the UI will attempt to compress it, which will break the plugin.)

  1. Go to Apps > Develop Apps > Create device.
    • In the Upnp Device Filename text box, enter D_CaddxNX584Security.xml.
    • Give the device a name in the Description text box.
  2. Go to Serial Port Configuration and assign the serial port (local or IPSerial) to the Luup device you just created.
  3. Save.
  4. After Luup restarts, refresh the browser.

Attachments