Version 7 (modified by chris, 13 years ago) (diff)

--

Welcome to the EDS One Wire Server Plugin for Vera

Discussion here: http://forum.micasaverde.com/index.php?topic=8381.0

Overview of OW-Server

The plugin implements an interface for the Embedded Data Systems OW-Server (see http://www.embeddeddatasystems.com/OW-SERVER--1-Wire-to-Ethernet-Server_p_152.htm). This is a low cost Ethernet to One-Wire system interface that can be used to interface to a number of environmental sensors. The OW-Server supports a line of advanced environmental sensors from EDS such as temperature, humidity, pressure, light, but also low cost Dallas sensors such as the DS18B20 temperature sensor. The OW-Server supports up to 24 physical devices, although many devices support multiple sensors - in this case, the plugin will provide an individual child device for each sensor.

Installation

Upload the files using the "MiOS Developers" button. Click on Luup Files and upload the 5 files for the plugin.

Create a new device with the following parameters -:

Click "Create Device". Restart Luup.

Usage

Once the plugin is installed, it will show the number of devices detected on the one-wire bus. You can then click on the properties box, and you will be presented with a tab called "Add Devices". If there are any devices that have not been added as Vera devices, they will be listed here. It's worth understanding how this (currently!) works. In the case of the EDS-ENV range of environmental sensors, many sensors are available on a single device (e.g. temperature, pressure, humidity, dewpoint, and a control relay). You will be presented with a list of the possible devices, and you can select how you want these mapped into Vera devices. It's also possible to select "Ignore", in which case no device will be created. It's important to understand that (currently) once any sensors have been added to Vera from a physical on-wire device, they will not be listed in this window again. So - make sure you add all the variables you want at the beginning!

Once you've selected all the sensors you want added, click the "Add" button and the sensors will be created. It will take some time before the data is actually updated within the Vera device, this is because the plugin performs some averaging to limit the amount of noise on the data. Sensors are typically provided with a single decimal place output (e.g. 15.2 degC, or 45.1% humidity), so this is done to avoid unnecessary data fluctuations.

Energy Monitoring

Some of the sensor options have "+ Energy". If you select this type, then the plugin will also set the Vera energy variables so that the energy monitoring system is updated when the sensor changes. The OW-Sensor plugin uses a variable "DeviceWatts?" in the ADVANCED tab to set this - set it to the number of watts that is being consumed when the sensor is active.

A Note About Sensors

EDS OW-ENV Sensors: LED and Relay Use

Both the LED and Relays inside the EDS OW-ENV sensors can be configured to provide a binary switch interface within Vera. For this to work correctly, you need to use the OW-Server web interface to set the LEDFunction or RelayFunction variables to value 2. This allows them to be controlled externally.

EDS D2Photo: Light Sensor

The D2Photo, light presence/absence monitor, provides the ability to monitor the state of fluorescent or incandescent lighting. It uses the DS2406 multidrop controller. This is quite a common chip and is used in a number of units. The OW-Sensor Plugin doesn't know if you have a D2Photo connected, or something else with the DS2406. It therefore lists a number of options for the DS2406 - it is recommended that you only use InputLevel_A (set InputLevel_B to Ignore), and select either Light Sensor, or Light Sensor + Energy. The only difference is that with the "+Energy" option, the plugin will set the energy monitoring variable so that you can use it to monitor power. In this way, if you are using the D2Photo to monitor a light status, you can also have the Vera energy monitoring system update correctly.